JOURNAL TRANSCRIPT
CiSE
ORIGINAL ARTICLE
Clinics in Shoulder and Elbow
Clinics in Shoulder and Elbow Vol. 18, No. 3, September, 2015 http://dx.doi.org/10.5397/cise.2015.18.3.128
PHILOS Plate Osteosynthesis in Metaphyseal Fractures of the Distal Humerus through an Anterolateral Approach Jung Ho Park , Jung Wook Kim, Chi Hun Oh1, Keun Seok Choi2, Jae Young Hong, Jae Gyoon Kim Department of Orthopedic Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 1Department of Orthopaedic Surgery, Barun Joint Hospital, Seongnam, 2Department of Orthopaedic Surgery, Burteam Hospital, Osan, Korea
Background: We described a surgical method for osteosynthesis and reported the resultant strength after application of a PHILOS plate through the anterolateral approach for the treatment of fractures of the distal humerus. Methods: Between February 2010 and March 2012, open reduction and internal fixation operations with the PHILOS plate for treatment of fracture of the distal humerus were performed on a total of nine patients (five men, four women). The mean age was 40.8 years (range, 24–50 years), and the average follow-up period was 9.1 months (range, 6–15 months). Clinical evaluations were performed 6 months after the operation. Clinical assessment included determination of the range of motion of the elbow, the Mayo and Oxford elbow scores, and any postoperative complications. Results: Fracture union was noted in all patients, with an average period of 12.4 weeks. The average Mayo elbow and Oxford elbow scores were 87.2 (of a total of 100) and 43.3 (of a total of 48), respectively. For the postoperative range of motion of the elbow, all patients showed complete recovery to the preoperative range of motion. No other conditions, such as neurolepsis, plate breakage, or rotational deformity, were observed. Conclusions: Open reduction and internal fixation of distal humerus fractures with a PHILOS plating system via anterolateral approach can be effective. A high rate of union with good outcomes can be assumed. (Clin Shoulder Elbow 2015;18(3):128-132) Key Words: Humeral fractures; Fracture fixation
Introduction Distal humerus fractures account for 30% of periarticular fractures of the elbow in adults, approximately 0.5% to 2.0% of the total reported incidence of fractures.1) The elbow is among the joints that are vulnerable to contracture, for which rigid fixation and quick joint movement recovery is important.2-4) Thus far, various operating methods and instruments have been introduced and successful results have been reported in some cases.5-7) The recent trend shows that treatment of transcondylar fractures through the posterior approach is associated with exact articular fixation and early joint mobility after a rigid fixation.8) For a shaft fracture, either open reduction by the anterolateral approach or
fixation by intramedullary nailing is widely accepted as the most suitable approach. In the case of metaphyseal fractures with inadequate space for fixation to the humerus, several techniques have been reported as effective, including orthogonal plating and parallel plating. However, no optimal technique or instrument has been identified. In general, the posterior approach is most often used for surgical treatment of fractures of the distal humerus.9-11) The posterior approach is associated with certain problems such as bleeding, decrease in muscular strength of the triceps, and formation of scar tissue, thereby leading to a limitation in the range of motion of the elbow.12) We describe a useful method involving locking screw fixation
Received October 28, 2014. Revised February 28, 2015. Accepted March 5, 2015. Correspondence to: Jung Ho Park Department of Orthopedic Surgery, Korea University Ansan Hospital, Korea University College of Medicine, 123 Jeokgeum-ro, Danwon-gu, Ansan 15355, Korea Tel: +82-31-412-5040, Fax: +82-31-439-3852, E-mail:
[email protected] Financial support: None. Conflict of interests: None. Copyright © 2015 Korean Shoulder and Elbow Society. All Rights Reserved. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
pISSN 2383-8337 eISSN 2288-8721
Novel Treatment for Distal Humerus Fractures Jung Ho Park, et al.
for cases of distal humerus shaft fracture and metaphyseal fracture in which the distal fractured portion is not sufficient for use of a plate such as the locking compression plate. The PHILOS plate (Synthes, Oberdorf, Switzerland) was recently introduced and has mainly been used for fractures of the proximal humerus. However, it can also provide adequate reduction and rigid fixation in metaphyseal fractures of the distal humerus; a suitable fixation owing to the well-conformed anatomical framework between the plate and the anterior surface of the distal humerus; and adequate power for fixation with multi-directional locking screws. In the current study, we described a surgical method for osteosynthesis and reported the resultant strength after application of a PHILOS plate through the anterolateral approach for treatment of fractures of the distal humerus.
Methods Between February 2010 and March 2012, open reduction and internal fixation operations with the PHILOS plate for treatment of fracture of the distal humeral shaft were performed in Korea University Ansan Hospital. A total of nine patients (five men, four women) were enrolled in the current study. The mean age was 40.8 years (range, 24–50 years), and the average followup period was 9.1 months (range, 6–15 months). The causes of injury were misstepping in five patients, traffic accidents in three patients, and fall in one patient (Table 1). Preoperative radiographic images of the anteroposterior, lateral, and oblique sides of the elbow were obtained for all patients. In cases where invasion of the joint was suspected, a computed tomography scan was also obtained. The fractures were classified according to the Orthopedic Trauma Association fracture and dislocation classification compendium, and its grade indicated 13-A2.1, 13-A2.2, 12-A1.3, 12-A2.3, and 12-B1.3.13) In some cases where that the patient’s general condition was poor, conservative treatment was administered. A regular plate
was used in cases where the fracture level was middle 1/3. The PHILOS plate was used in extraarticular fracture where the level was distal 1/3 of the humeral shaft. The details of the surgical methodology were as follows: To facilitate an anterolateral approach, patients were placed on the operating table in a supine position under general anesthesia and with the forearm supinated. Using the anterolateral approach, a 7 to 10 cm longitudinal skin incision was made and fasciotomy was then performed along the lateral side of the biceps brachii muscle, which was then drawn medially by retractors. After confirming the brachialis muscle, the middle portion of the muscle was incised longitudinally. As the brachialis muscle was split between the musculocutaneous and radial nerves, it was possible to prevent muscular denervation and brachialis muscle dysfunction.9) Therefore, the radial nerve was positioned on the lateral side of the brachialis muscle, which was naturally protected. After dissecting the brachialis muscle, the bone was exposed and adequate traction and reduction were applied. A lag screw was used in the case of an oblique fracture after the reduction of the fracture. In cases of transverse and communited
Fig. 1. The anterolateral surgical approach and PHILOS plate fixation. The distal humerus is identified by splitting the brachialis muscle in line with its fibers.
Table 1. Clinical Data for All 9 Patients Patient No.
Sex
Age (yr)
OTA classification
Follow-up period (mo)
Time to union (wk)
Flexion contracture (o)
Further flexion (o)
Mayo elbow score
Oxford elbow score
1
Female
49
13-A2.1
Fall down
15
13
5
130
75
36
2
Male
24
13-A2.1
Traffic accident
6
10
0
140
100
48
3
Male
40
12-A2.3
Slipped down
6
11
5
130
85
43
4
Female
5
Male
38
13-A2.1
Slipped down
7
11
0
135
95
46
38
12-A2.3
Slipped down
7
12
0
135
90
41
6
Female
49
12-B1.3
Traffic accident
10
14
5
135
75
38
7
Male
49
13-A2.1
Slipped down
12
14
0
130
80
44
8
Female
50
13-A2.2
Slipped down
13
16
0
130
90
47
9
Male
30
12-A1.3
Traffic accident
6
11
0
140
95
47
Cause
www.cisejournal.org
129
Clinics in Shoulder and Elbow Vol. 18, No. 3, September, 2015
fractures, the PHILOS plate was applied immediately. The plate was inserted between the brachialis fibers and positioned on the anterior surface of the distal humerus (Fig. 1). Reduction of fracture and suitability between bone and plate was checked using a C-arm system. The plate was well contoured on the anterior surface of the distal humerus. The plate length and position were also checked. Note that the plate should be positioned in the middle portion of the bone, and the distal potion of the plate should be placed above the coronoid fossa to prevent limitation of the range of motion. Thereafter, K-wire fixation was performed through a screw hole for temporary stabilization. Three locking head screws were then inserted in the proximal fragment. In the distal potion, we tried to use as many locking head screws as possible; owing to the features of this plate, a minimum of four and maximum of nine could be inserted (Fig. 2). Finally, the reduction and fixation were checked by using the Carm, and the operation was completed after massive irrigation. A long-arm splint was applied postoperatively. Once pain had
subsided after 2 to 3 days, gradual movement of the joint was permitted. Radiographic images of the anteroposterior, lateral, and both oblique sides were again obtained immediately after the operation for assessment of fracture reduction, plate position, and screw position (Fig. 3). Postoperative radiological assessments were performed every four weeks to check for nonunion, malunion, or delayed union in the patients in the ambulatory state. Clinical evaluations were performed six months after the operation. Clinical assessment included determination of the range of motion of the elbow, the Mayo and Oxford elbow scores, and any postoperative complications.
Results Fracture union was noted in all of the patients, with an average period of 12.4 weeks. The average Mayo elbow and Oxford elbow scores were 87.2 (of a total of 100) and 43.3 (of a total of
Fig. 2. Characteristics of the PHILOS plate. The PHILOS plate fits well on the anterior portion of the distal humerus. It can achieve rigid fixation by use of multidirectional locking screws.
A
B
Fig. 3. Case of a 50-year-old woman who sustained a fracture in an accident. (A) A plain radiograph indicating a spiral fracture of the distal humerus. (B) Open reduction and internal fixation was performed using a PHILOS plate and three lag screws.
130
www.cisejournal.org
Novel Treatment for Distal Humerus Fractures Jung Ho Park, et al.
48), respectively (Table 2). For the postoperative range of motion of the elbow, all patients showed complete recovery to the preoperative range of motion. No other conditions, such as neurolepsis, plate breakage, or rotational deformity, were observed.
Case Example In our research, we experienced an interesting case. A 63-year-old woman visited our hospital because of a distal humerus fracture after a fall. She had undergone a total elbow arthroplasty ten years ago. The previously inserted humeral stem interfered with the conventional screw insertion. Therefore, we decided to apply a PHILOS plate on this periprosthetic fracture. The PHILOS plate was placed slightly obliquely on the anterior portion of the distal humerus to avoid contact with the interamedullary stem. As characteristic of the PHILOS plate, the
Table 2. Summary of Cases Variable
Value
Mean duration for bone union (wk)
12.4
Mayo elbow performance score Excellent (90–100)
5
Good (75–89)
4
Fair (60–74)
0
Poor (